Ozone (O3) gas detector
Fixed ozone (O3) detectors for water and air disinfection, cold room treatment and processes: electrochemical cell, 0-1 or 0-5 ppm, 4-20 mA outputs, Modbus and relays depending on the model. Choose the model below to see its specifications and options.
Fixed ozone (O3) detectors for water and air disinfection, cold room treatment and processes: electrochemical cell, 0-1 or 0-5 ppm, 4-20 mA outputs, Modbus and relays depending on the model.
Why detect ozone?
Ozone is used to disinfect water, air and rooms, including fruit and vegetable cold rooms. It is effective but irritates the airways: the level must stay low where staff work, and the ozone generator must be controlled.
The sensor
Electrochemical cell, 0-1 ppm (personal safety) or 0-5 ppm ranges, 0.01 ppm resolution. Operation from −20 to +40 °C on 0-1 ppm and −40 to +50 °C on 0-5 ppm; lifetime over 18 months (0-1 ppm) or 2 years (0-5 ppm).
Where to install an ozone detector?
At breathing height in working areas, and near the ozone generator and injection points.
Available models
| Model | Sensor | Ranges | Housing | Outputs | Local alarm |
|---|---|---|---|---|---|
| E2638-O3 | electrochemical | 0-1 or 0-5 ppm | grey ABS, IP65, 90 × 145 × 55 mm | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display |
| E2639-O3 | electrochemical | 0-1 or 0-5 ppm | grey ABS, IP65, 190 mm wide | 2 × 4-20 mA, RS485 Modbus RTU, optional WiFi | 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs |
| E2608-O3 | electrochemical | 0-1 or 0-5 ppm | grey ABS, IP65, 87 × 82 × 55 mm, wall or duct | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | 2 SPST relays 5 A |
| E2618-O3 | electrochemical | 0-1 or 0-5 ppm | grey ABS, IP65, 82 × 80 × 55 mm, wall or duct | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | none: alarm handled by the PLC |
| E2648-O3 | electrochemical | 0-1 or 0-5 ppm | die-cast aluminium, IP66, 120 × 125 × 57 mm | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | optional 2 SPST relays 5 A |
Choose the model in the list at the top of the page to see all its specifications and options. Other measuring ranges are available on request.
Alarm and options by model
- E2638 : optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display ; relays, buzzer and LEDs, built-in or remote LCD display (0 to +50 °C), self-test button, 3 m remote probe, 90-265 VAC.
- E2639 : 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs ; WiFi with web server, replaceable pre-calibrated GSH sensor, 2.5 or 5 m remote probe (GSH version).
- E2608 : 2 SPST relays 5 A ; duct version, 3 m remote probe, 24 VAC or 230 VAC.
- E2618 : none: alarm handled by the PLC ; duct version, 3 m remote probe.
- E2648 : optional 2 SPST relays 5 A ; relays, 3 m remote probe, 24 VAC or 230 VAC.
Request a quote
Afric Froid supplies and installs Evikon gas detectors with its refrigeration systems in Tunisia, Algeria, Senegal and Côte d’Ivoire. Tell us the room, its temperature, the number of points to monitor, the power supply and how the alarm should be given: we select the model and send you a quote.
See all our gas detectors and sensors.
| Model | E2638-O3 · multi-option IP65, E2639-O3 · 3 relays, buzzer, E2608-O3 · 2 relays, wall/duct, E2618-O3 · transmitter, no relays, E2648-O3 · aluminium IP66 |
|---|