VOC and solvent vapour gas detector

Fixed volatile organic compound (VOC) and solvent vapour detectors for paint shops, printing works and chemical stores: semiconductor sensor (ppm or % LEL) or PID photo-ionisation, 0-40 / 0-200 ppm. Choose the model below to see its specifications and options.

Request a quote

SKU: N/A Category:
Description

Fixed volatile organic compound (VOC) and solvent vapour detectors for paint shops, printing works and chemical stores: semiconductor sensor (ppm or % LEL) or PID photo-ionisation, 0-40 / 0-200 ppm.

Why detect VOCs?

Solvents (toluene, acetone, alcohols, white spirit…) evaporate in paint shops, printing works, laboratories and chemical stores. They are harmful with prolonged exposure and flammable at high concentration. Detection protects staff, controls the ventilation and reveals a leak or a spill.

Two types of sensors

  • Semiconductor (VOC versions): rugged and cost-effective, measures up to 0-1,000 ppm (toxic range) or 0-100 % LEL (flammable range), calibrated on toluene by default, operation from −40 to +70 °C, lifetime over 5 years, yearly check. It responds to many solvents: it detects presence rather than measuring one specific product.
  • Photo-ionisation (PID versions): precise measurement of low levels, 0-40 or 0-200 ppm, 0.01 ppm resolution on 0-40 ppm, operation from −40 to +65 °C, lifetime over 5 years. It is the choice for industrial hygiene.

Where to install a VOC detector?

Most solvent vapours are heavier than air: install the detector low, near workstations, tanks and storage areas, away from supply air outlets.

Available models

Model Sensor Ranges Housing Outputs Local alarm
E2638-VOC metal-oxide semiconductor (MOS) up to 0-1,000 ppm (toxic range) or 0-100 % LEL (flammable range) grey ABS, IP65, 90 × 145 × 55 mm 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display
E2638-PID photo-ionisation detector (PID) 0-40 or 0-200 ppm grey ABS, IP65, 90 × 145 × 55 mm 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display
E2639-VOC metal-oxide semiconductor (MOS) up to 0-1,000 ppm (toxic range) or 0-100 % LEL (flammable range) grey ABS, IP65, 190 mm wide 2 × 4-20 mA, RS485 Modbus RTU, optional WiFi 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs
E2639-PID photo-ionisation detector (PID) 0-40 or 0-200 ppm grey ABS, IP65, 190 mm wide 2 × 4-20 mA, RS485 Modbus RTU, optional WiFi 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs
E2608-VOC metal-oxide semiconductor (MOS) up to 0-1,000 ppm (toxic range) or 0-100 % LEL (flammable range) grey ABS, IP65, 87 × 82 × 55 mm, wall or duct 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU 2 SPST relays 5 A
E2608-PID photo-ionisation detector (PID) 0-40 or 0-200 ppm grey ABS, IP65, 87 × 82 × 55 mm, wall or duct 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU 2 SPST relays 5 A
E2618-VOC metal-oxide semiconductor (MOS) up to 0-1,000 ppm (toxic range) or 0-100 % LEL (flammable range) grey ABS, IP65, 82 × 80 × 55 mm, wall or duct 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU none: alarm handled by the PLC
E2618-PID photo-ionisation detector (PID) 0-40 or 0-200 ppm grey ABS, IP65, 82 × 80 × 55 mm, wall or duct 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU none: alarm handled by the PLC
E2648-VOC metal-oxide semiconductor (MOS) up to 0-1,000 ppm (toxic range) or 0-100 % LEL (flammable range) die-cast aluminium, IP66, 120 × 125 × 57 mm 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU optional 2 SPST relays 5 A
E2648-PID photo-ionisation detector (PID) 0-40 or 0-200 ppm die-cast aluminium, IP66, 120 × 125 × 57 mm 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU optional 2 SPST relays 5 A
E2630-VOC metal-oxide semiconductor (MOS) 0-100 to 0-1,000 ppm, or 0-100 % LEL grey ABS, IP65, 145 mm wide no analog output (UART) 2 SPDT relays 5 A, LED and 85 dB buzzer, magnetic key test
E2610-VOC metal-oxide semiconductor (MOS) 0-500 ppm or 0-100 % LEL slotted ABS, IP20, 85 × 85 × 37 mm, dry rooms no analog output (UART) 2 SPDT relays 5 A, LED and 85 dB buzzer

Choose the model in the list at the top of the page to see all its specifications and options. Other measuring ranges are available on request.

Alarm and options by model

  • E2638 : optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display ; relays, buzzer and LEDs, built-in or remote LCD display (0 to +50 °C), self-test button, 3 m remote probe, 90-265 VAC.
  • E2639 : 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs ; WiFi with web server, replaceable pre-calibrated GSH sensor, 2.5 or 5 m remote probe (GSH version).
  • E2608 : 2 SPST relays 5 A ; duct version, 3 m remote probe, 24 VAC or 230 VAC.
  • E2618 : none: alarm handled by the PLC ; duct version, 3 m remote probe.
  • E2648 : optional 2 SPST relays 5 A ; relays, 3 m remote probe, 24 VAC or 230 VAC.
  • E2630 : 2 SPDT relays 5 A, LED and 85 dB buzzer, magnetic key test ; 24 V or 230 V power supply.
  • E2610 : 2 SPDT relays 5 A, LED and 85 dB buzzer ; 24 V or 230 V power supply.

Request a quote

Afric Froid supplies and installs Evikon gas detectors with its refrigeration systems in Tunisia, Algeria, Senegal and Côte d’Ivoire. Tell us the room, its temperature, the number of points to monitor, the power supply and how the alarm should be given: we select the model and send you a quote.

See all our gas detectors and sensors.

Additional information
ModelE2638-VOC · MOS · multi-option IP65, E2638-PID · PID · multi-option IP65, E2639-VOC · MOS · 3 relays, buzzer, E2639-PID · PID · 3 relays, buzzer, E2608-VOC · MOS · 2 relays, wall/duct, E2608-PID · PID · 2 relays, wall/duct, E2618-VOC · MOS · transmitter, no relays, E2618-PID · PID · transmitter, no relays, E2648-VOC · MOS · aluminium IP66, E2648-PID · PID · aluminium IP66, E2630-VOC · MOS · IP65 alarm, buzzer, E2610-VOC · MOS · compact IP20 alarm