Ethylene oxide (ETO) gas detector

Fixed ethylene oxide (C2H4O, ETO) detectors for medical device sterilisers and fumigation plants: electrochemical cell, 0-20 or 0-100 ppm. Not to be confused with the ethylene C2H4 of ripening rooms. Choose the model below to see its specifications and options.

Request a quote

SKU: N/A Category:
Description

Fixed ethylene oxide (C2H4O, ETO) detectors for medical device sterilisers and fumigation plants: electrochemical cell, 0-20 or 0-100 ppm. Not to be confused with the ethylene C2H4 of ripening rooms.

Ethylene oxide, a sterilisation gas

Ethylene oxide (C2H4O, ETO) sterilises medical devices and is used for some fumigations. Toxic and flammable, it must be monitored around sterilisers, aerators and cartridge or cylinder storage. Note: it is a different gas from the ethylene (C2H4) of ripening rooms, which has its own detector.

The sensor

Electrochemical cell, 0-20 or 0-100 ppm ranges, operation from −20 to +50 °C, response time under 120 s, lifetime over 2 years, checked every 6 months.

Where to install an ethylene oxide detector?

Near steriliser and aerator doors, connection points and storage, at breathing height in working areas.

Available models

Model Sensor Ranges Housing Outputs Local alarm
E2638-ETO electrochemical 0-20 or 0-100 ppm grey ABS, IP65, 90 × 145 × 55 mm 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display
E2639-ETO electrochemical 0-20 or 0-100 ppm grey ABS, IP65, 190 mm wide 2 × 4-20 mA, RS485 Modbus RTU, optional WiFi 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs
E2608-ETO electrochemical 0-20 or 0-100 ppm grey ABS, IP65, 87 × 82 × 55 mm, wall or duct 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU 2 SPST relays 5 A
E2618-ETO electrochemical 0-20 or 0-100 ppm grey ABS, IP65, 82 × 80 × 55 mm, wall or duct 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU none: alarm handled by the PLC
E2648-ETO electrochemical 0-20 or 0-100 ppm die-cast aluminium, IP66, 120 × 125 × 57 mm 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU optional 2 SPST relays 5 A

Choose the model in the list at the top of the page to see all its specifications and options. Other measuring ranges are available on request.

Alarm and options by model

  • E2638 : optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display ; relays, buzzer and LEDs, built-in or remote LCD display (0 to +50 °C), self-test button, 3 m remote probe, 90-265 VAC.
  • E2639 : 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs ; WiFi with web server, replaceable pre-calibrated GSH sensor, 2.5 or 5 m remote probe (GSH version).
  • E2608 : 2 SPST relays 5 A ; duct version, 3 m remote probe, 24 VAC or 230 VAC.
  • E2618 : none: alarm handled by the PLC ; duct version, 3 m remote probe.
  • E2648 : optional 2 SPST relays 5 A ; relays, 3 m remote probe, 24 VAC or 230 VAC.

Request a quote

Afric Froid supplies and installs Evikon gas detectors with its refrigeration systems in Tunisia, Algeria, Senegal and Côte d’Ivoire. Tell us the room, its temperature, the number of points to monitor, the power supply and how the alarm should be given: we select the model and send you a quote.

See all our gas detectors and sensors.

Additional information
ModelE2638-ETO · multi-option IP65, E2639-ETO · 3 relays, buzzer, E2608-ETO · 2 relays, wall/duct, E2618-ETO · transmitter, no relays, E2648-ETO · aluminium IP66
Documentation

Official Evikon documents, kept up to date by the manufacturer: