Hydrogen sulphide (H2S) gas detector
Fixed hydrogen sulphide (H2S) detectors for wastewater plants, sewers, pits and processes: electrochemical cell, 0-100 or 0-2,000 ppm, 4-20 mA outputs, Modbus and relays depending on the model. Choose the model below to see its specifications and options.
Fixed hydrogen sulphide (H2S) detectors for wastewater plants, sewers, pits and processes: electrochemical cell, 0-100 or 0-2,000 ppm, 4-20 mA outputs, Modbus and relays depending on the model.
Where is H2S found?
Hydrogen sulphide forms when organic matter decomposes without oxygen: wastewater treatment plants, sewer networks and lift stations, pits, slurry tanks, food industries. Very toxic, it smells of rotten eggs at low levels, but the sense of smell quickly gets used to it and gives no protection at high concentrations.
The sensor
Electrochemical cell, 0-100 ppm (personal safety) or 0-2,000 ppm (process) ranges, operation from −30 to +50 °C (−40 °C on 0-2,000 ppm), response time under 30 s, lifetime over 2 years, checked every 6 months.
Where to install an H2S detector?
H2S is heavier than air: install the detector low, near the sources and in low points (pits, trenches, manholes), with a remote alarm at the room entrance.
Available models
| Model | Sensor | Ranges | Housing | Outputs | Local alarm |
|---|---|---|---|---|---|
| E2638-H2S | electrochemical | 0-100 or 0-2,000 ppm | grey ABS, IP65, 90 × 145 × 55 mm | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display |
| E2639-H2S | electrochemical | 0-100 or 0-2,000 ppm | grey ABS, IP65, 190 mm wide | 2 × 4-20 mA, RS485 Modbus RTU, optional WiFi | 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs |
| E2608-H2S | electrochemical | 0-100 or 0-2,000 ppm | grey ABS, IP65, 87 × 82 × 55 mm, wall or duct | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | 2 SPST relays 5 A |
| E2618-H2S | electrochemical | 0-100 or 0-2,000 ppm | grey ABS, IP65, 82 × 80 × 55 mm, wall or duct | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | none: alarm handled by the PLC |
| E2648-H2S | electrochemical | 0-100 or 0-2,000 ppm | die-cast aluminium, IP66, 120 × 125 × 57 mm | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | optional 2 SPST relays 5 A |
Choose the model in the list at the top of the page to see all its specifications and options. Other measuring ranges are available on request.
Alarm and options by model
- E2638 : optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display ; relays, buzzer and LEDs, built-in or remote LCD display (0 to +50 °C), self-test button, 3 m remote probe, 90-265 VAC.
- E2639 : 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs ; WiFi with web server, replaceable pre-calibrated GSH sensor, 2.5 or 5 m remote probe (GSH version).
- E2608 : 2 SPST relays 5 A ; duct version, 3 m remote probe, 24 VAC or 230 VAC.
- E2618 : none: alarm handled by the PLC ; duct version, 3 m remote probe.
- E2648 : optional 2 SPST relays 5 A ; relays, 3 m remote probe, 24 VAC or 230 VAC.
Request a quote
Afric Froid supplies and installs Evikon gas detectors with its refrigeration systems in Tunisia, Algeria, Senegal and Côte d’Ivoire. Tell us the room, its temperature, the number of points to monitor, the power supply and how the alarm should be given: we select the model and send you a quote.
See all our gas detectors and sensors.
| Model | E2638-H2S · multi-option IP65, E2639-H2S · 3 relays, buzzer, E2608-H2S · 2 relays, wall/duct, E2618-H2S · transmitter, no relays, E2648-H2S · aluminium IP66 |
|---|
Official Evikon documents, kept up to date by the manufacturer:
Related products
Refrigerant gas detector (HFC, HFO, R32, R290)
Combustible gas detector (methane, LPG, propane)
Fixed combustible and explosive gas detectors for boiler rooms, industrial kitchens, propane rooms and machinery rooms: methane, natural gas, propane, butane, LPG, hydrogen, measured from 0 to 100 % LEL. Stand-alone alarms or 4-20 mA transmitters. Choose the model below to see its specifications and options.






