Ethylene (C2H4) gas detector

Fixed ethylene C2H4 detectors and sensors for banana ripening rooms, citrus degreening and fruit and vegetable storage: electrochemical sensor from 0-10 to 0-1,500 ppm, from −40 to +50 °C and up to 100 % humidity. Choose the model below to see its specifications and options.

Request a quote

SKU: N/A Category:
Description

Fixed ethylene C2H4 detectors and sensors for banana ripening rooms, citrus degreening and fruit and vegetable storage: electrochemical sensor from 0-10 to 0-1,500 ppm, from −40 to +50 °C and up to 100 % humidity.

Why measure ethylene?

Ethylene (C2H4) is the ripening hormone of fruit. In ripening rooms it is injected to trigger even ripening of bananas, avocados or mangoes, and for citrus degreening. In storage, on the contrary, it must be removed: a few ppm are enough to speed up the ripening and ageing of apples, kiwis or sensitive vegetables. In both cases, a reliable and continuous measurement of the ethylene level in the room is needed.

Which measuring range?

Use Recommended range
Fruit and vegetable storage, low-level monitoring 0-10 ppm
Citrus degreening 0-20 ppm (E2639)
Ripening rooms (bananas, avocados, mangoes) 0-200 ppm or 0-500 ppm (E2639)
Injection control and high concentrations 0-1,500 ppm

The 0-10, 0-20 and 0-200 ppm ranges are the ones recommended in the Evikon catalogue for ripening and degreening.

The Evikon electrochemical sensor

  • selective ethylene measurement, 0.1 ppm resolution on the 0-10 ppm range;
  • operation from −40 to +50 °C and up to 100 % relative humidity: suitable for very humid fruit and vegetable cold rooms;
  • response time under 60 s, checked every 6 months, lifetime over 2 years;
  • 4-20 mA / 0-10 V outputs and Modbus to control ethylene injection or extraction from the ripening room controller.

Do not confuse ethylene (C2H4) with ethylene oxide (C2H4O), a toxic sterilisation gas: it has its own ethylene oxide detector.

A complete ripening room

A ripening room is controlled with three measurements: ethylene, the CO2 released by the fruit, and humidity and temperature (E2218 or E2228 transmitters). Afric Froid designs and installs cold rooms and ripening rooms: we can include gas detection from the design stage.

Available models

Model Sensor Ranges Housing Outputs Local alarm
E2638-C2H4 electrochemical 0-10, 0-200 or 0-1,500 ppm grey ABS, IP65, 90 × 145 × 55 mm 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display
E2639-C2H4 electrochemical 0-10, 0-20, 0-200, 0-500 or 0-1,500 ppm grey ABS, IP65, 190 mm wide 2 × 4-20 mA, RS485 Modbus RTU, optional WiFi 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs
E2608-C2H4 electrochemical 0-10, 0-200 or 0-1,500 ppm grey ABS, IP65, 87 × 82 × 55 mm, wall or duct 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU 2 SPST relays 5 A
E2618-C2H4 electrochemical 0-10, 0-200 or 0-1,500 ppm grey ABS, IP65, 82 × 80 × 55 mm, wall or duct 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU none: alarm handled by the PLC
E2648-C2H4 electrochemical 0-10, 0-200 or 0-1,500 ppm die-cast aluminium, IP66, 120 × 125 × 57 mm 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU optional 2 SPST relays 5 A

Choose the model in the list at the top of the page to see all its specifications and options. Other measuring ranges are available on request.

Alarm and options by model

  • E2638 : optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display ; relays, buzzer and LEDs, built-in or remote LCD display (0 to +50 °C), self-test button, 3 m remote probe, 90-265 VAC.
  • E2639 : 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs ; WiFi with web server, replaceable pre-calibrated GSH sensor, 2.5 or 5 m remote probe (GSH version).
  • E2608 : 2 SPST relays 5 A ; duct version, 3 m remote probe, 24 VAC or 230 VAC.
  • E2618 : none: alarm handled by the PLC ; duct version, 3 m remote probe.
  • E2648 : optional 2 SPST relays 5 A ; relays, 3 m remote probe, 24 VAC or 230 VAC.

Request a quote

Afric Froid supplies and installs Evikon gas detectors with its refrigeration systems in Tunisia, Algeria, Senegal and Côte d’Ivoire. Tell us the room, its temperature, the number of points to monitor, the power supply and how the alarm should be given: we select the model and send you a quote.

See all our gas detectors and sensors.

Additional information
ModelE2638-C2H4 · multi-option IP65, E2639-C2H4 · 3 relays, buzzer, E2608-C2H4 · 2 relays, wall/duct, E2618-C2H4 · transmitter, no relays, E2648-C2H4 · aluminium IP66
Documentation

Official Evikon documents, kept up to date by the manufacturer: