Ethylene oxide (ETO) gas detector
Fixed ethylene oxide (C2H4O, ETO) detectors for medical device sterilisers and fumigation plants: electrochemical cell, 0-20 or 0-100 ppm. Not to be confused with the ethylene C2H4 of ripening rooms. Choose the model below to see its specifications and options.
Fixed ethylene oxide (C2H4O, ETO) detectors for medical device sterilisers and fumigation plants: electrochemical cell, 0-20 or 0-100 ppm. Not to be confused with the ethylene C2H4 of ripening rooms.
Ethylene oxide, a sterilisation gas
Ethylene oxide (C2H4O, ETO) sterilises medical devices and is used for some fumigations. Toxic and flammable, it must be monitored around sterilisers, aerators and cartridge or cylinder storage. Note: it is a different gas from the ethylene (C2H4) of ripening rooms, which has its own detector.
The sensor
Electrochemical cell, 0-20 or 0-100 ppm ranges, operation from −20 to +50 °C, response time under 120 s, lifetime over 2 years, checked every 6 months.
Where to install an ethylene oxide detector?
Near steriliser and aerator doors, connection points and storage, at breathing height in working areas.
Available models
| Model | Sensor | Ranges | Housing | Outputs | Local alarm |
|---|---|---|---|---|---|
| E2638-ETO | electrochemical | 0-20 or 0-100 ppm | grey ABS, IP65, 90 × 145 × 55 mm | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display |
| E2639-ETO | electrochemical | 0-20 or 0-100 ppm | grey ABS, IP65, 190 mm wide | 2 × 4-20 mA, RS485 Modbus RTU, optional WiFi | 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs |
| E2608-ETO | electrochemical | 0-20 or 0-100 ppm | grey ABS, IP65, 87 × 82 × 55 mm, wall or duct | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | 2 SPST relays 5 A |
| E2618-ETO | electrochemical | 0-20 or 0-100 ppm | grey ABS, IP65, 82 × 80 × 55 mm, wall or duct | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | none: alarm handled by the PLC |
| E2648-ETO | electrochemical | 0-20 or 0-100 ppm | die-cast aluminium, IP66, 120 × 125 × 57 mm | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | optional 2 SPST relays 5 A |
Choose the model in the list at the top of the page to see all its specifications and options. Other measuring ranges are available on request.
Alarm and options by model
- E2638 : optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display ; relays, buzzer and LEDs, built-in or remote LCD display (0 to +50 °C), self-test button, 3 m remote probe, 90-265 VAC.
- E2639 : 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs ; WiFi with web server, replaceable pre-calibrated GSH sensor, 2.5 or 5 m remote probe (GSH version).
- E2608 : 2 SPST relays 5 A ; duct version, 3 m remote probe, 24 VAC or 230 VAC.
- E2618 : none: alarm handled by the PLC ; duct version, 3 m remote probe.
- E2648 : optional 2 SPST relays 5 A ; relays, 3 m remote probe, 24 VAC or 230 VAC.
Request a quote
Afric Froid supplies and installs Evikon gas detectors with its refrigeration systems in Tunisia, Algeria, Senegal and Côte d’Ivoire. Tell us the room, its temperature, the number of points to monitor, the power supply and how the alarm should be given: we select the model and send you a quote.
See all our gas detectors and sensors.
| Model | E2638-ETO · multi-option IP65, E2639-ETO · 3 relays, buzzer, E2608-ETO · 2 relays, wall/duct, E2618-ETO · transmitter, no relays, E2648-ETO · aluminium IP66 |
|---|
Official Evikon documents, kept up to date by the manufacturer:
Related products
CO2 gas detector (R744)
Ethylene (C2H4) gas detector
Combustible gas detector (methane, LPG, propane)
Fixed combustible and explosive gas detectors for boiler rooms, industrial kitchens, propane rooms and machinery rooms: methane, natural gas, propane, butane, LPG, hydrogen, measured from 0 to 100 % LEL. Stand-alone alarms or 4-20 mA transmitters. Choose the model below to see its specifications and options.