Fixed carbon monoxide (CO) detectors for car parks, loading bays, warehouses with combustion-engine forklifts and boiler rooms: electrochemical cell from 0-100 to 0-1,000 ppm, lifetime over 10 years. Relay and buzzer alarms, or 4-20 mA transmitters for ventilation control. Choose the model below to see its specifications and options.
Fixed carbon monoxide (CO) detectors for car parks, loading bays, warehouses with combustion-engine forklifts and boiler rooms: electrochemical cell from 0-100 to 0-1,000 ppm, lifetime over 10 years. Relay and buzzer alarms, or 4-20 mA transmitters for ventilation control.
Why detect carbon monoxide?
Carbon monoxide (CO) forms during incomplete combustion: petrol engines, gas or diesel forklifts, poorly adjusted boilers and burners. It is invisible, odourless and very toxic, even at low concentration. In an underground car park, a closed loading bay or a warehouse with combustion-engine forklifts, its measurement controls the ventilation, which only runs at full speed when needed. In a boiler room, it reveals a poorly adjusted burner or a flue gas problem.
The sensor
All models use an electrochemical cell, selective and stable: ranges from 0-100 to 0-1,000 ppm depending on the model, operation from −20 to +50 °C, response time under 30 s, lifetime over 10 years and a yearly check. The choice is mainly about how the alarm is given: stand-alone alarm with buzzer and relays (E2630, E2610), transmitter for the building management system (E2617, E2618) or complete detector (E2638, E2639, E2608, E2648).
Where to install a CO detector?
CO has a density close to that of air: the detector is installed at breathing height, between 1.5 and 1.8 m, in traffic areas and near the sources (ramps, loading stations, boilers). In a car park, plan one detector for a few hundred square metres depending on the layout; we calculate it with you. For diesel engines, add a NO2 detector.
Available models
| Model | Sensor | Ranges | Housing | Outputs | Local alarm |
|---|---|---|---|---|---|
| E2638-CO | electrochemical | 0-300 or 0-1,000 ppm | grey ABS, IP65, 90 × 145 × 55 mm | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display |
| E2639-CO | electrochemical | 0-300 or 0-1,000 ppm | grey ABS, IP65, 190 mm wide | 2 × 4-20 mA, RS485 Modbus RTU, optional WiFi | 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs |
| E2608-CO | electrochemical | 0-300 or 0-1,000 ppm | grey ABS, IP65, 87 × 82 × 55 mm, wall or duct | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | 2 SPST relays 5 A |
| E2618-CO | electrochemical | 0-300 or 0-1,000 ppm | grey ABS, IP65, 82 × 80 × 55 mm, wall or duct | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | none: alarm handled by the PLC |
| E2648-CO | electrochemical | 0-300 or 0-1,000 ppm | die-cast aluminium, IP66, 120 × 125 × 57 mm | 2 × 4-20 mA / 0-10 V, RS485 Modbus RTU | optional 2 SPST relays 5 A |
| E2630-CO | electrochemical | 0-200 ppm (standard) or 0-1,000 ppm | grey ABS, IP65, 145 mm wide | no analog output (UART) | 2 SPDT relays 5 A, LED and 85 dB buzzer, magnetic key test |
| E2610-CO | electrochemical | 0-200 ppm (standard) or 0-1,000 ppm | slotted ABS, IP20, 85 × 85 × 37 mm, dry rooms | no analog output (UART) | 2 SPDT relays 5 A, LED and 85 dB buzzer |
| E2617-CO | electrochemical | 0-100, 0-200 or 0-300 ppm | ABS, IP65, 82 × 94 × 35 mm | 1 × 4-20 mA or 0-10 V | none: alarm handled by the PLC |
Choose the model in the list at the top of the page to see all its specifications and options. Other measuring ranges are available on request.
Alarm and options by model
- E2638 : optional: 2 relays 5 A, LEDs and 85 dB buzzer or LCD display ; relays, buzzer and LEDs, built-in or remote LCD display (0 to +50 °C), self-test button, 3 m remote probe, 90-265 VAC.
- E2639 : 3 relays (pre-alarm, alarm, fault), 4 LEDs, 85 dB buzzer, 2 × 24 V beacon outputs ; WiFi with web server, replaceable pre-calibrated GSH sensor, 2.5 or 5 m remote probe (GSH version).
- E2608 : 2 SPST relays 5 A ; duct version, 3 m remote probe, 24 VAC or 230 VAC.
- E2618 : none: alarm handled by the PLC ; duct version, 3 m remote probe.
- E2648 : optional 2 SPST relays 5 A ; relays, 3 m remote probe, 24 VAC or 230 VAC.
- E2630 : 2 SPDT relays 5 A, LED and 85 dB buzzer, magnetic key test ; 24 V or 230 V power supply.
- E2610 : 2 SPDT relays 5 A, LED and 85 dB buzzer ; 24 V or 230 V power supply.
- E2617 : none: alarm handled by the PLC ; none.
Request a quote
Afric Froid supplies and installs Evikon gas detectors with its refrigeration systems in Tunisia, Algeria, Senegal and Côte d’Ivoire. Tell us the room, its temperature, the number of points to monitor, the power supply and how the alarm should be given: we select the model and send you a quote.
See all our gas detectors and sensors.
| Model | E2638-CO · multi-option IP65, E2639-CO · 3 relays, buzzer, E2608-CO · 2 relays, wall/duct, E2618-CO · transmitter, no relays, E2648-CO · aluminium IP66, E2630-CO · IP65 alarm, buzzer, E2610-CO · compact IP20 alarm, E2617-CO · low-cost transmitter |
|---|