Danfoss EVR 40 v2 solenoid valve

Danfoss EVR 40 refrigeration solenoid valve (EVR v2), servo operated (piston), Kv 24.2 m³/h: about 249.7 kW in the liquid line with R404A. 6 models, normally closed. Valve body sold without coil. Choose your model below to see its specifications.

Request a quote

SKU: N/A Category:
Description

The Danfoss EVR 40 (version 2) is a servo operated (piston) solenoid valve for the liquid, suction and hot gas lines of refrigeration and air conditioning systems. With a Kv of 24.2 m³/h, it handles about 249.7 kW in the liquid line with R404A and 368.7 kW with R22 or R407C, at Danfoss rated conditions. It is available normally closed (NC), solder 1 5/8″, 2 1/8″, 42 mm. The valve body is sold without coil.

The models

Code Type Function Connection Manual Kv (m³/h) Weight
032L1110 EVR 40 NC 1 5/8″ solder no 24.2 4.43 kg
032L1109 EVR 40 NC 1 5/8″ solder yes 24.2 4.31 kg
032L1112 EVR 40 NC 2 1/8″ solder no 24.2 4.53 kg
032L1111 EVR 40 NC 2 1/8″ solder yes 24.2 4.59 kg
032L1114 EVR 40 NC 42 mm solder no 24.2 4.41 kg
032L1113 EVR 40 NC 42 mm solder yes 24.2 4.25 kg

NC = normally closed (closed with coil de-energized), NO = normally open (open with coil de-energized). Valve bodies supplied without coil.

Rated capacity (kW)

Line R22/R407C R134a R404A/R507 R410A
Liquid 368.74 341.15 249.71 361.49
Suction 40.35 29.12 35.21 50.85
Hot gas 217.22 167.43 178.27 266.74

Danfoss values. Liquid and suction: evaporating −10 °C, liquid at 25 °C ahead of the valve, pressure drop 0.15 bar. Hot gas: condensing 40 °C, pressure drop 0.8 bar, hot gas at 65 °C, subcooling 4 K. For other conditions, we run the calculation with Danfoss Coolselector.

Specifications

  • Operation: servo operated (piston). Minimum opening differential pressure 0.2 bar.
  • MOPD (maximum opening differential pressure, liquid line): 38 bar with a 10 W AC coil, 17 bar with a 20 W DC coil.
  • Pressures: 45.2 bar maximum working pressure (solder versions).
  • Media temperature: −40 to 105 °C, and up to 130 °C during defrost.
  • Refrigerants: R22, R134a, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R507A, R513A, R515B, R1234ze(E)… Flammable refrigerants must be checked with us for each code.
  • Construction: brass body, extended copper ends on solder versions, so the valve does not need to be dismantled for brazing.
  • Manual operation (“+ manual” models): a stem opens the NC valve with the coil de-energized, in about 6 turns, for example for evacuation or troubleshooting. Close it again and refit the cap afterwards.
  • Test magnet: any EVR NC or NO valve can also be opened or closed by hand, with the coil removed, using the Danfoss 018F0091 magnet.

Coil

The valve body is sold without coil. EVR valves take the Danfoss clip-on coils: the standard coil is the BE230AS (018F6701, 230 V AC, IP67 terminal box), as given in the Danfoss data sheet. The maximum opening differential pressure (MOPD) depends on the coil: the values given here are those of the Danfoss data sheet, with a 10 W AC or 20 W DC coil. For an ATEX zone, see the BV024A coil.

All sizes are listed in our Danfoss EVR v2 solenoid valve range, with a selection table. Neighbouring sizes: EVR 32. For a reversible circuit, see the EVRC bi-flow solenoid valve.

Afric Froid, your Danfoss supplier

Afric Froid supplies Danfoss solenoid valves, coils and valves, installs them and provides after-sales service in Tunisia, Algeria, Senegal and Ivory Coast. Tell us the refrigerant, the capacity and the line (liquid, suction or hot gas): we will choose the right valve and coil and send you a quote.

Additional information
Model1 5/8″ solder · NC (032L1110), 1 5/8″ solder · NC + manual (032L1109), 2 1/8″ solder · NC (032L1112), 2 1/8″ solder · NC + manual (032L1111), 42 mm solder · NC (032L1114), 42 mm solder · NC + manual (032L1113)
Documentation

Official Danfoss documents for EVR v2 solenoid valves, always in their latest version: