Danfoss AK-CC 750A evaporator controller

Danfoss AK-CC 750A controller from the ADAP-KOOL range for refrigerated display cases and cold rooms. It controls 1 to 4 evaporators with AKV or stepper motor electronic expansion valves, and handles the thermostat, defrosts, fans, lights and alarms. Danfoss ref. 080Z0140.

Request a quote

SKU: 080Z0140 Category:
Description

The AK-CC 750A is a complete evaporator controller for refrigerated display cases and chilled or frozen cold rooms. Together with its valves and sensors, it replaces the day/night thermostats and the control of defrosts, fans, rail heat, lights and alarms. It controls up to 4 evaporator sections, each with its own electronic expansion valve, and grows with extension modules as the system grows.

Key benefits

  • 1 to 4 evaporators with a single controller, for a display case or a cold room with several evaporators.
  • Adaptive superheat: electronic injection with an AKV valve, or with an ETS or CCMT stepper motor valve using the AK-XM 208C module. The evaporator stays well filled in all operating conditions.
  • Adaptive defrost: the controller uses the valve opening to follow ice build-up. It cancels unnecessary defrosts and starts one on its own when the evaporator begins to block.
  • Thermostat: day/night, weighted and alarm thermostat; on/off or modulating solenoid valve, for direct expansion as well as brine systems.
  • Case functions: cleaning, lights from the door switch or the network, rail heat pulsing by day/night or dew point, door alarm.
  • Log of measurements and alarms, exportable to Excel or AKM software.

Specifications

  • Supply 24 V AC or DC ±20%, 8 VA; one class II transformer per controller.
  • 11 analogue inputs: Pt1000 sensors or PTC1000, AKS 32R, AKS 2050 or AKS 32 (1–5 V) pressure transmitters, 0–10 V signals and contacts.
  • 8 outputs: 4 solid state outputs (AKV valves, fans, rail heat) and 4 relays.
  • Up to 11 AK-XM extension modules for more inputs, relays or stepper valve outputs.
  • LON communication to the ADAP-KOOL network and an AK-SM 800A system manager; PC setup with AK-ST 500 software (USB port).
  • Up to 4 EKA 163B or EKA 164B displays for temperatures (with a 2 m cable or a 6 m cable), or the MMIGRS2 graphic display.
  • DIN rail or wall mounting, IP10 (to be fitted in an electrical panel), ambient temperature −20 to 55 °C, 0 to 95% RH non-condensing.

Modules and accessories

Module Function Danfoss ref.
AK-XM 101A 8 analogue inputs 080Z0007
AK-XM 102A 8 low voltage digital inputs (80 V max.) 080Z0008
AK-XM 102B 8 high voltage digital inputs (260 V max.) 080Z0013
AK-XM 103A 4 analogue inputs, 4 outputs 0–10 V 080Z0032
AK-XM 204A / 204B 8 relays (204B: with manual override) 080Z0011 / 080Z0018
AK-XM 205A / 205B 8 analogue inputs, 8 relays (205B: with override) 080Z0010 / 080Z0017
AK-XM 208C 8 analogue inputs, 4 outputs for stepper valves 080Z0023
AK-OB 110 2 outputs 0–10 V, fitted inside the controller 080Z0251
AK-PS 075 / AK-PS 150 power supply 230/115 V to 24 V, 18 or 36 VA 080Z0053 / 080Z0054
EKA 163B / EKA 164B display / display with buttons 084B8574 / 084B8575
MMIGRS2 graphic display with keys 080G0294
Display cables EKA 2 m or 6 m; MMIGRS2 1.5 m or 3 m 084B7298 / 084B7299; 080G0075 / 080G0076
AK-ST 500 PC setup software 080Z0161

Afric Froid, your Danfoss supplier

Afric Froid supplies Danfoss AK-CC 750A controllers and their extension modules, installs them and provides after-sales service in Tunisia, Algeria, Senegal and Ivory Coast. Describe your system: we will define the modules you need and send you a quote.

Documentation

Official Danfoss document for the AK-CC 750A controller:

  • AK-CC 750A user guide (PDF, 10.5 MB): modules, wiring, configuration, control functions, alarms and ordering codes.