Danfoss EVR 25 refrigeration solenoid valve (EVR v2), servo operated (piston), Kv 9.8 m³/h: about 101.1 kW in the liquid line with R404A. 6 models, normally closed. Valve body sold without coil. Choose your model below to see its specifications.
The Danfoss EVR 25 (version 2) is a servo operated (piston) solenoid valve for the liquid, suction and hot gas lines of refrigeration and air conditioning systems. With a Kv of 9.8 m³/h, it handles about 101.1 kW in the liquid line with R404A and 149.2 kW with R22 or R407C, at Danfoss rated conditions. It is available normally closed (NC), solder 1 1/8″, 1 3/8″, 28 mm. The valve body is sold without coil.
The models
| Code | Type | Function | Connection | Manual | Kv (m³/h) | Weight |
|---|---|---|---|---|---|---|
| 032L2201 | EVR 25 | NC | 1 1/8″ solder | no | 9.8 | 2.69 kg |
| 032L2200 | EVR 25 | NC | 1 1/8″ solder | yes | 9.8 | 2.73 kg |
| 032L2208 | EVR 25 | NC | 1 3/8″ solder | no | 9.8 | 2.71 kg |
| 032L2207 | EVR 25 | NC | 1 3/8″ solder | yes | 9.8 | 2.74 kg |
| 032L2206 | EVR 25 | NC | 28 mm solder | no | 9.8 | 2.63 kg |
| 032L2205 | EVR 25 | NC | 28 mm solder | yes | 9.8 | 2.72 kg |
NC = normally closed (closed with coil de-energized), NO = normally open (open with coil de-energized). Valve bodies supplied without coil.
Rated capacity (kW)
| Line | R22/R407C | R134a | R404A/R507 | R410A |
|---|---|---|---|---|
| Liquid | 149.23 | 138.06 | 101.06 | 146.30 |
| Suction | 16.33 | 11.79 | 14.25 | 20.58 |
| Hot gas | 87.87 | 67.73 | 72.12 | 107.91 |
Danfoss values. Liquid and suction: evaporating −10 °C, liquid at 25 °C ahead of the valve, pressure drop 0.15 bar. Hot gas: condensing 40 °C, pressure drop 0.8 bar, hot gas at 65 °C, subcooling 4 K. For other conditions, we run the calculation with Danfoss Coolselector.
Specifications
- Operation: servo operated (piston). Minimum opening differential pressure 0.2 bar.
- MOPD (maximum opening differential pressure, liquid line): 38 bar with a 10 W AC coil, 17 bar with a 20 W DC coil.
- Pressures: 45.2 bar maximum working pressure (solder versions).
- Media temperature: −40 to 105 °C, and up to 130 °C during defrost.
- Refrigerants: R22, R134a, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R507A, R513A, R515B, R1234ze(E)… Flammable refrigerants must be checked with us for each code.
- Construction: brass body, extended copper ends on solder versions, so the valve does not need to be dismantled for brazing.
- Manual operation (“+ manual” models): a stem opens the NC valve with the coil de-energized, in about 6 turns, for example for evacuation or troubleshooting. Close it again and refit the cap afterwards.
- Test magnet: any EVR NC or NO valve can also be opened or closed by hand, with the coil removed, using the Danfoss 018F0091 magnet.
Coil
The valve body is sold without coil. EVR valves take the Danfoss clip-on coils: the standard coil is the BE230AS (018F6701, 230 V AC, IP67 terminal box), as given in the Danfoss data sheet. The maximum opening differential pressure (MOPD) depends on the coil: the values given here are those of the Danfoss data sheet, with a 10 W AC or 20 W DC coil. For an ATEX zone, see the BV024A coil.
All sizes are listed in our Danfoss EVR v2 solenoid valve range, with a selection table. Neighbouring sizes: EVR 22 and EVR 32. For a reversible circuit, see the EVRC bi-flow solenoid valve.
Afric Froid, your Danfoss supplier
Afric Froid supplies Danfoss solenoid valves, coils and valves, installs them and provides after-sales service in Tunisia, Algeria, Senegal and Ivory Coast. Tell us the refrigerant, the capacity and the line (liquid, suction or hot gas): we will choose the right valve and coil and send you a quote.
| Model | 1 1/8″ solder · NC (032L2201), 1 1/8″ solder · NC + manual (032L2200), 1 3/8″ solder · NC (032L2208), 1 3/8″ solder · NC + manual (032L2207), 28 mm solder · NC (032L2206), 28 mm solder · NC + manual (032L2205) |
|---|
Official Danfoss documents for EVR v2 solenoid valves, always in their latest version:
- EVR 2 - EVR 40 data sheet (PDF, 2025 edition, 3.3 MB): operation, codes, capacities and dimensions, including EVRC and flammable refrigerants.
- EVR 25 installation guide (PDF, 0.3 MB): mounting, brazing and tightening torques.