Geneglace ice plant
Flake ice plants from 1 to 11 tonnes per day (up to 12 t with water at 5 °C), built by Afric Froid around a Geneglace generator (France) and a Bock semi-hermetic compressor (Germany). 6 models, from FG1T to FG10T. The ice comes out dry and subcooled, in flakes of 2 to 2.5 mm. Select your model below to display its components and its production at 30 °C and at 38 °C.
Our flake ice plants combine a Geneglace generator, made in France, with a Bock semi-hermetic compressor, made in Germany. Afric Froid mounts them on a frame with the air-cooled condenser, the refrigeration circuit and the electrical panel. The range has 6 models, from 1 to 11 tonnes of ice per day. Each model is rated at 30 °C and at 38 °C ambient air, for the hottest sites.
The 6 models from 1 to 11 tonnes per day
| Model | Production at 30 °C | Production at 38 °C | Thickness | Generator | Bock compressor | Cooling −22 / +48 °C | Max. current |
|---|---|---|---|---|---|---|---|
| FG1T | 1.0 t | 0.95 t | 2.0 to 2.1 mm | F30 | HGX34e/315-4 S (12 HP) | 6.4 kW | 15 A |
| FG2T | 2.3 t | 2.1 t | 2.3 to 2.4 mm | F90H | HGX44e/475-4 S (18 HP) | 10.7 kW | 23 A |
| FG3T | 3.0 t | 2.8 t | 2.2 to 2.3 mm | F90V | HGX44e/665-4 S (25 HP) | 14.7 kW | 30 A |
| FG5T | 5.6 t | 5.4 t | 2.2 mm | F200 | HGX56e/1155-4 (38 HP) | 26.0 kW | 46.9 A |
| FG8T | 9.0 t | 8.0 t | 2 to 2.5 mm | F250 | HGX66e/2070-4 (69 HP) | 47.6 kW | 85.1 A |
| FG10T | 11.0 t | 10.0 t | 2 to 2.5 mm | F600 | HGX88e/2735-4 (91 HP) | 64.1 kW | 116 A |
Production in tonnes of ice per 24 h, with R404A. At 30 °C air: make-up water at 18 °C (FG10T: 15 °C). At 38 °C air: water at 20 °C. With make-up water at 5 °C, the FG10T produces up to 12 t/day. Cooling capacity and maximum current of the compressor alone, from the Bock VAP software: evaporating −22 °C and condensing +48 °C at dew point, superheat 10 K, subcooling 3 K. Horsepower (HP) is calculated from the maximum power input in the Bock catalogue (1 metric HP = 0.7355 kW).
The Geneglace ice generator
The generator is a fixed vertical cylinder with a double wall in machined, polished and chrome-plated steel, insulated with injected polyurethane. Water runs down the cold wall and freezes. A helical cutter, driven by a variable-speed geared motor, removes the ice continuously. Two scrapers, before and after the cutter, leave dry, subcooled ice that releases easily.
All parts in contact with water are stainless steel: distribution and collection trays, cutter, scraper holder, insulated base. The flooded surge drum keeps the cylinder filled with refrigerant and protects the compressor from liquid return. The generator is supplied with its submerged water pump. It complies with the PED and ASME codes, and its manufacture is inspected by an independent body.
| Generator | Geneglace range | Dimensions L × W × H | Weight | Installed power | Model |
|---|---|---|---|---|---|
| F30 | 0.6 to 1 t/day | 65 × 50 × 70 cm | 90 kg | 250 W | FG1T |
| F90 | 1.6 to 3.5 t/day | 89 × 73 × 126 cm | 250 kg | 250 W | FG2T, FG3T |
| F200 | 4.5 to 6.5 t/day | 120 × 92 × 176 cm | 720 kg | 320 W | FG5T |
| F250 | 7 to 10 t/day | 130 × 97 × 205 cm | 900 kg | 320 W | FG8T |
| F600 | 10 to 14 t/day | 150 × 120 × 205 cm | 950 kg | 390 W | FG10T |
Generator only, from the Geneglace documentation. Actual production depends on the evaporating temperature and on the cutter speed: the faster the cutter turns, the thinner the ice.
The Bock compressor
Each plant has a Bock semi-hermetic reciprocating compressor of the latest generation: HG34e and HG44e series with 4 cylinders, HG56e and HG66e with 6 cylinders, HG88e with 8 cylinders. The HG66e and HG88e have the mexxFlow valve plate, which reduces pressure losses. The stator can be replaced on site without special tools, and lubrication is by oil pump. The data for each series are on our HG34e, HG44e, HG56e, HG66e and HG88e pages.
What the plant includes
Refrigeration circuit
- Oil separator, oil return solenoid valve and sight glass
- Discharge check valve
- Oversized air-cooled condenser, made in Europe
- Horizontal liquid receiver with shut-off valves
- Filter drier with replaceable core and liquid sight glass
- Liquid solenoid valve, manual expansion valve and ball valve
- Refrigerant level regulator
- Two pressure transmitters and an oil pressure gauge
- Copper piping insulated with Armaflex
Compressor
- Suction and discharge shut-off valves
- Combined HP / LP pressure switch and oil differential pressure switch
- Built-in motor protection
Generator
- Submerged water pump
- Safety limit stop
Electrical panel
- Built to CE standards, with a mimic diagram on the front
- Danfoss MCX controller: settings, operation and faults
- Circuit breakers and contactors for the compressor, fans, pump and scraper
- On / off, manual operation of the pump and scraper, emergency stop and resets
- Alarms: high and low pressure, compressor, condenser, scraper, pump, overheating
Not included
- Civil works
- Water supply, power supply and water treatment
- Lifting and positioning of the machine
- Transport to the site
Options: anti-corrosion epoxy-coated condenser fins for seaside sites, insulated silo to store the ice.
Above 11 tonnes per day
For higher production, Geneglace makes the F800 (14 to 20 t/day), F900 (20 to 30 t/day) and F2000 (40 to 50 t/day) generators, for HFC refrigerants or ammonia (R717). There are also seawater generators, such as the F90 SWT (2.7 t/day). These machines are designed project by project. Example: a 10 to 12 t/day flake ice plant in Mahdia.
Frequently asked questions
What cooling capacity is needed for 1 tonne of ice per day?
About 5 kW at the evaporator with water at 15 °C, and 2.5% more with water at 20 °C. This is the rule of the Geneglace selection software. The compressor is selected with a margin to keep the production in hot weather.
Why two production values?
The hotter the air, the higher the condensing pressure and the less cooling the compressor produces. The make-up water is also warmer. We therefore give the production at 30 °C and at 38 °C ambient air.
Can the ice thickness be adjusted?
Yes. The faster the cutter turns, the thinner the ice. Our machines are set for flakes of 2 to 2.5 mm.
Can a refrigerant other than R404A be used?
Yes. The generator works with current refrigerants, including R449A and R448A, and the large models with ammonia. The production varies slightly with the refrigerant: we recalculate it for each project.
Afric Froid and ice plants
Afric Froid designs, builds and installs its ice plants, then provides commissioning and after-sales service in Tunisia, Algeria, Senegal and Côte d’Ivoire. Frigo Indus is ISO 9001:2015 certified by DQS for the design, manufacture, sale, installation and after-sales service of refrigeration machines. Tell us the production you need, the air temperature and the water temperature: we make the selection and send you a quote.
See also: ice cube plant, tube ice plant, Snowkey ice plant and all our ice plants.
| Model | FG1T – 0.95 to 1 t/day – F30, FG2T – 2.1 to 2.3 t/day – F90H, FG3T – 2.8 to 3 t/day – F90V, FG5T – 5.4 to 5.6 t/day – F200, FG8T – 8 to 9 t/day – F250, FG10T – 10 to 11 t/day – F600 |
|---|
Official Geneglace document: